Powermax DFBG Power Plant
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model | 200CFBG | 400CFBG | 500CFBG | 600CFBG | 800CFBG | 1000CFBG | 1200CFBG | 1500CFBG | 2000CFBG |
Rated Power(kw) | 200 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | ||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | ||||||||
Model of Gasifier | CFBG200 | CFBG400 | CFBG500 | CFBG600 | CFBG800 | CFBG1000 | CFBG1200 | CFBG1500 | CFBG2000 |
Gasifier Type | Circulating Fluidized Bed Gasifier(CFBG) | ||||||||
Biomass Moisture Requirement | ≤20%(wet basis) | ||||||||
Biomass Size Requirment | ≤8-15mm | ||||||||
Biomass Consumption(Kg/hr) | 200-360 | 400-720 | 500-900 | 600-1080 | 800-1440 | 1000-1800 | 1200-2160 | 1500-2700 | 2000-3600 |
Gas Production(Nm3/h) | 500-600 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Dry Ash Type | ||||||||
Type of Gas Purification | POWERMAX Semi Dry Type Gas Purification System | ||||||||
Heat Value of Gas | 1200-1300Kcal/Nm3 | ||||||||
Gas Composition | CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% | ||||||||
Model of Gensent | 100GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 2 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model | 200CFBG | 400CFBG | 500CFBG | 600CFBG | 800CFBG | 1000CFBG | 1200CFBG | 1500CFBG | 2000CFBG |
Rated Power(kw) | 200 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | ||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | ||||||||
Model of Gasifier | CFBG200 | CFBG400 | CFBG500 | CFBG600 | CFBG800 | CFBG1000 | CFBG1200 | CFBG1500 | CFBG2000 |
Gasifier Type | Circulating Fluidized Bed Gasifier(CFBG) | ||||||||
Biomass Moisture Requirement | ≤20%(wet basis) | ||||||||
Biomass Size Requirment | ≤8-15mm | ||||||||
Biomass Consumption(Kg/hr) | 200-360 | 400-720 | 500-900 | 600-1080 | 800-1440 | 1000-1800 | 1200-2160 | 1500-2700 | 2000-3600 |
Gas Production(Nm3/h) | 500-600 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Dry Ash Type | ||||||||
Type of Gas Purification | POWERMAX Semi Dry Type Gas Purification System | ||||||||
Heat Value of Gas | 1200-1300Kcal/Nm3 | ||||||||
Gas Composition | CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% | ||||||||
Model of Gensent | 100GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 2 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)
- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation System
Model | 50TFBG | 100TFBG | 200TFBG | 300TFBG | 400TFBG | 500TFBG | 600TFBG | 800TFBG | 1000TFBG | 1200TFBG | 1500TFBG | 2000TFBG |
Rated Power(kw) | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | |||||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | |||||||||||
Model of Gasifier | TFBG50 | TFBG100 | TFBG200 | TFBG300 | TFBG400 | TFBG500 | TFBG600 | TFBG800 | TFBG1000 | TFBG1200 | TFBG1500 | TFBG2000 |
Gasifier Type | Twin-Fire Fixed Bed Gasifier | |||||||||||
Biomass Moisture Requirement | ≤20~35%(wet basis) | |||||||||||
Biomass Size Requirment | Diameter 20mm-80mm;Length 10-80mm; | |||||||||||
Biomass Consumption(Kg/hr) | 50-100 | 100-200 | 200-400 | 300-600 | 400-800 | 500-1000 | 600-1200 | 800-1600 | 1000-2000 | 1200-2400 | 1500-3000 | 2000-4000 |
Gas Production(Nm3/h) | 125-150 | 250-300 | 500-600 | 750-900 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Wet Ash Type/ Dry Ash Type | |||||||||||
Type of Gas Purification | Dry Type Gas Purification System | |||||||||||
Heat Value of Gas | ≥1200Kcal/Nm3 | |||||||||||
Gas Composition | CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% | |||||||||||
Model of Gensent | 50GFLS | 100GFLS | 100GFLS | 300GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 1 | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
-
-
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model 200CFBG 400CFBG 500CFBG 600CFBG 800CFBG 1000CFBG 1200CFBG 1500CFBG 2000CFBG Rated Power(kw) 200 400 500 600 800 1000 1200 1500 2000 Rated Frequency 50 /60 HZ Rated Voltage(V) 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 Model of Gasifier CFBG200 CFBG400 CFBG500 CFBG600 CFBG800 CFBG1000 CFBG1200 CFBG1500 CFBG2000 Gasifier Type Circulating Fluidized Bed Gasifier(CFBG) Biomass Moisture Requirement ≤20%(wet basis) Biomass Size Requirment ≤8-15mm Biomass Consumption(Kg/hr) 200-360 400-720 500-900 600-1080 800-1440 1000-1800 1200-2160 1500-2700 2000-3600 Gas Production(Nm3/h) 500-600 1000-1200 1250-1500 1500-1800 2000-2400 2500-3000 3000-3600 3750-4500 5000-6000 Ash Discharge Type Dry Ash Type Type of Gas Purification POWERMAX Semi Dry Type Gas Purification System Heat Value of Gas 1200-1300Kcal/Nm3 Gas Composition CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% Model of Gensent 100GFLS 400GFLS 500GFLS 300GFLS 400GFLS 1000GFLS 400GFLS 500GFLS 1000GFLS Qty of Genset 2 1 1 2 2 1 3 3 2
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation SystemModel 50TFBG 100TFBG 200TFBG 300TFBG 400TFBG 500TFBG 600TFBG 800TFBG 1000TFBG 1200TFBG 1500TFBG 2000TFBG Rated Power(kw) 50 100 200 300 400 500 600 800 1000 1200 1500 2000 Rated Frequency 50 /60 HZ Rated Voltage(V) 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 Model of Gasifier TFBG50 TFBG100 TFBG200 TFBG300 TFBG400 TFBG500 TFBG600 TFBG800 TFBG1000 TFBG1200 TFBG1500 TFBG2000 Gasifier Type Twin-Fire Fixed Bed Gasifier Biomass Moisture Requirement ≤20~35%(wet basis) Biomass Size Requirment Diameter 20mm-80mm;Length 10-80mm; Biomass Consumption(Kg/hr) 50-100 100-200 200-400 300-600 400-800 500-1000 600-1200 800-1600 1000-2000 1200-2400 1500-3000 2000-4000 Gas Production(Nm3/h) 125-150 250-300 500-600 750-900 1000-1200 1250-1500 1500-1800 2000-2400 2500-3000 3000-3600 3750-4500 5000-6000 Ash Discharge Type Wet Ash Type/ Dry Ash Type Type of Gas Purification Dry Type Gas Purification System Heat Value of Gas ≥1200Kcal/Nm3 Gas Composition CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% Model of Gensent 50GFLS 100GFLS 100GFLS 300GFLS 400GFLS 500GFLS 300GFLS 400GFLS 1000GFLS 400GFLS 500GFLS 1000GFLS Qty of Genset 1 1 2 1 1 1 2 2 1 3 3 2
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
-
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)
- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation System
Model | 50TFBG | 100TFBG | 200TFBG | 300TFBG | 400TFBG | 500TFBG | 600TFBG | 800TFBG | 1000TFBG | 1200TFBG | 1500TFBG | 2000TFBG |
Rated Power(kw) | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | |||||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | |||||||||||
Model of Gasifier | TFBG50 | TFBG100 | TFBG200 | TFBG300 | TFBG400 | TFBG500 | TFBG600 | TFBG800 | TFBG1000 | TFBG1200 | TFBG1500 | TFBG2000 |
Gasifier Type | Twin-Fire Fixed Bed Gasifier | |||||||||||
Biomass Moisture Requirement | ≤20~35%(wet basis) | |||||||||||
Biomass Size Requirment | Diameter 20mm-80mm;Length 10-80mm; | |||||||||||
Biomass Consumption(Kg/hr) | 50-100 | 100-200 | 200-400 | 300-600 | 400-800 | 500-1000 | 600-1200 | 800-1600 | 1000-2000 | 1200-2400 | 1500-3000 | 2000-4000 |
Gas Production(Nm3/h) | 125-150 | 250-300 | 500-600 | 750-900 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Wet Ash Type/ Dry Ash Type | |||||||||||
Type of Gas Purification | Dry Type Gas Purification System | |||||||||||
Heat Value of Gas | ≥1200Kcal/Nm3 | |||||||||||
Gas Composition | CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% | |||||||||||
Model of Gensent | 50GFLS | 100GFLS | 100GFLS | 300GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 1 | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
- 1. Biomass Storage
- 2. Biomass Conveyor
- 3. Biomass Gasifier
- 4. Cyclone Dust Collector
- 5. Air Cooler
- 6. Gas Cooler
- 7. ESP
- 8. Gas Cooler
- 9. Gas Dryer
- 10. Buffer Tank
- 11. Gas Flare
- 12. Gas Generator Sets
- 13. Blower
Technical Specification of DFBG series Biomass Gasification Power Generation System
Model | 50DFBG | 100DFBG | 200DFBG | 300DFBG | 400DFBG | 500DFBG | 600DFBG | 800DFBG | 1000DFBG |
Rated Power(kw) | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 |
Rated Frequency | 50 /60 HZ | ||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | ||||||||
Model of Gasifier | DFBG50 | DFBG100 | DFBG200 | DFBG300 | DFBG400 | DFBG500 | DFBG600 | DFBG800 | DFBG1000 |
Gasifier Type | Downdraft Fixed Bed Gasifier | ||||||||
Biomass Moisture Requirement | ≤16%(wet basis) | ||||||||
Biomass Size Requirment | Less than 1cm | ||||||||
Biomass Consumption(Kg/hr) | 50-100 | 100-200 | 200-400 | 300-600 | 400-800 | 500-1000 | 600-1200 | 800-1600 | 1000-2000 |
Gas Production(Nm3/h) | 125-150 | 250-300 | 500-600 | 750-900 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 |
Ash Discharge Type | Dry Ash Type | ||||||||
Type of Gas Purification | Dry Type Gas Purification System | ||||||||
Heat Value of Gas | ≥1100Kcal/Nm3 | ||||||||
Gas Composition | CO-15~20%, CO2-8~12%, CH4-upto 4% H2-10~15% N2-45~55% | ||||||||
Model of Gensent | 50GFLS | 100GFLS | 100GFLS | 300GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS |
Qty of Genset | 1 | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 |
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model | 200CFBG | 400CFBG | 500CFBG | 600CFBG | 800CFBG | 1000CFBG | 1200CFBG | 1500CFBG | 2000CFBG |
Rated Power(kw) | 200 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | ||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | ||||||||
Model of Gasifier | CFBG200 | CFBG400 | CFBG500 | CFBG600 | CFBG800 | CFBG1000 | CFBG1200 | CFBG1500 | CFBG2000 |
Gasifier Type | Circulating Fluidized Bed Gasifier(CFBG) | ||||||||
Biomass Moisture Requirement | ≤20%(wet basis) | ||||||||
Biomass Size Requirment | ≤8-15mm | ||||||||
Biomass Consumption(Kg/hr) | 200-360 | 400-720 | 500-900 | 600-1080 | 800-1440 | 1000-1800 | 1200-2160 | 1500-2700 | 2000-3600 |
Gas Production(Nm3/h) | 500-600 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Dry Ash Type | ||||||||
Type of Gas Purification | POWERMAX Semi Dry Type Gas Purification System | ||||||||
Heat Value of Gas | 1200-1300Kcal/Nm3 | ||||||||
Gas Composition | CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% | ||||||||
Model of Gensent | 100GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 2 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)
- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation System
Model | 50TFBG | 100TFBG | 200TFBG | 300TFBG | 400TFBG | 500TFBG | 600TFBG | 800TFBG | 1000TFBG | 1200TFBG | 1500TFBG | 2000TFBG |
Rated Power(kw) | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | |||||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | |||||||||||
Model of Gasifier | TFBG50 | TFBG100 | TFBG200 | TFBG300 | TFBG400 | TFBG500 | TFBG600 | TFBG800 | TFBG1000 | TFBG1200 | TFBG1500 | TFBG2000 |
Gasifier Type | Twin-Fire Fixed Bed Gasifier | |||||||||||
Biomass Moisture Requirement | ≤20~35%(wet basis) | |||||||||||
Biomass Size Requirment | Diameter 20mm-80mm;Length 10-80mm; | |||||||||||
Biomass Consumption(Kg/hr) | 50-100 | 100-200 | 200-400 | 300-600 | 400-800 | 500-1000 | 600-1200 | 800-1600 | 1000-2000 | 1200-2400 | 1500-3000 | 2000-4000 |
Gas Production(Nm3/h) | 125-150 | 250-300 | 500-600 | 750-900 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Wet Ash Type/ Dry Ash Type | |||||||||||
Type of Gas Purification | Dry Type Gas Purification System | |||||||||||
Heat Value of Gas | ≥1200Kcal/Nm3 | |||||||||||
Gas Composition | CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% | |||||||||||
Model of Gensent | 50GFLS | 100GFLS | 100GFLS | 300GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 1 | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
- 1.Biomass Fuel Blower
- 2.Cyclone
- 3.Gasifier
- 4.Cyclone
- 5.Air Cooler
- 6.Indirect Cooler
- 7.Isolation Seal
- 8.ESP
- 9.Booster Fan
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Cooling Tower
- 16.Water Pump
- 17.Cooling Water Pool
- 18. Tar Tank
- 19.Condensate Water Pool
- 20.Pulse Dust Collector
- 21.Cyclone Dust Collector
- 22.Ash Tank
- 23.Ash Discharge Transition Hopper
- 24.Water Tank
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model | 200CFBG | 400CFBG | 500CFBG | 600CFBG | 800CFBG | 1000CFBG | 1200CFBG | 1500CFBG | 2000CFBG |
Rated Power(kw) | 200 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | ||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | ||||||||
Model of Gasifier | CFBG200 | CFBG400 | CFBG500 | CFBG600 | CFBG800 | CFBG1000 | CFBG1200 | CFBG1500 | CFBG2000 |
Gasifier Type | Circulating Fluidized Bed Gasifier(CFBG) | ||||||||
Biomass Moisture Requirement | ≤20%(wet basis) | ||||||||
Biomass Size Requirment | ≤8-15mm | ||||||||
Biomass Consumption(Kg/hr) | 200-360 | 400-720 | 500-900 | 600-1080 | 800-1440 | 1000-1800 | 1200-2160 | 1500-2700 | 2000-3600 |
Gas Production(Nm3/h) | 500-600 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Dry Ash Type | ||||||||
Type of Gas Purification | POWERMAX Semi Dry Type Gas Purification System | ||||||||
Heat Value of Gas | 1200-1300Kcal/Nm3 | ||||||||
Gas Composition | CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% | ||||||||
Model of Gensent | 100GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 2 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
-
Technical Specification of CFBG series Biomass Gasification Power Generation System
Model 200CFBG 400CFBG 500CFBG 600CFBG 800CFBG 1000CFBG 1200CFBG 1500CFBG 2000CFBG Rated Power(kw) 200 400 500 600 800 1000 1200 1500 2000 Rated Frequency 50 /60 HZ Rated Voltage(V) 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 Model of Gasifier CFBG200 CFBG400 CFBG500 CFBG600 CFBG800 CFBG1000 CFBG1200 CFBG1500 CFBG2000 Gasifier Type Circulating Fluidized Bed Gasifier(CFBG) Biomass Moisture Requirement ≤20%(wet basis) Biomass Size Requirment ≤8-15mm Biomass Consumption(Kg/hr) 200-360 400-720 500-900 600-1080 800-1440 1000-1800 1200-2160 1500-2700 2000-3600 Gas Production(Nm3/h) 500-600 1000-1200 1250-1500 1500-1800 2000-2400 2500-3000 3000-3600 3750-4500 5000-6000 Ash Discharge Type Dry Ash Type Type of Gas Purification POWERMAX Semi Dry Type Gas Purification System Heat Value of Gas 1200-1300Kcal/Nm3 Gas Composition CO-12~18%, CO2-10~16%, CH4-4~8% H2-3~7% CnHm-1~1.4% O2-0.5~1.2% N2-54~60% Model of Gensent 100GFLS 400GFLS 500GFLS 300GFLS 400GFLS 1000GFLS 400GFLS 500GFLS 1000GFLS Qty of Genset 2 1 1 2 2 1 3 3 2
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation SystemModel 50TFBG 100TFBG 200TFBG 300TFBG 400TFBG 500TFBG 600TFBG 800TFBG 1000TFBG 1200TFBG 1500TFBG 2000TFBG Rated Power(kw) 50 100 200 300 400 500 600 800 1000 1200 1500 2000 Rated Frequency 50 /60 HZ Rated Voltage(V) 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 Model of Gasifier TFBG50 TFBG100 TFBG200 TFBG300 TFBG400 TFBG500 TFBG600 TFBG800 TFBG1000 TFBG1200 TFBG1500 TFBG2000 Gasifier Type Twin-Fire Fixed Bed Gasifier Biomass Moisture Requirement ≤20~35%(wet basis) Biomass Size Requirment Diameter 20mm-80mm;Length 10-80mm; Biomass Consumption(Kg/hr) 50-100 100-200 200-400 300-600 400-800 500-1000 600-1200 800-1600 1000-2000 1200-2400 1500-3000 2000-4000 Gas Production(Nm3/h) 125-150 250-300 500-600 750-900 1000-1200 1250-1500 1500-1800 2000-2400 2500-3000 3000-3600 3750-4500 5000-6000 Ash Discharge Type Wet Ash Type/ Dry Ash Type Type of Gas Purification Dry Type Gas Purification System Heat Value of Gas ≥1200Kcal/Nm3 Gas Composition CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% Model of Gensent 50GFLS 100GFLS 100GFLS 300GFLS 400GFLS 500GFLS 300GFLS 400GFLS 1000GFLS 400GFLS 500GFLS 1000GFLS Qty of Genset 1 1 2 1 1 1 2 2 1 3 3 2
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
-
- 1.Elevator
- 2.Feed Bin
- 3.Gasifier
- 4.Cyclone
- 5.Tube Type Dust Remover
- 6.Venturi
- 7.Cyclone Hydraulic Separators
- 8.ESP
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Roots Blower
- 12.Buffer Tank
- 13.Vent Cans&Gas Flare
- 14.Tubular Heat Exchanger
- 15.Gas Generator Set
- 16.Cooling Tower
- 17.Air Blower
- 18.Water Pump
- 19.Cooling Water Pool
- 20.Condensate Water Pool
- 21.Tar Tank
- 22.Biochar Outlet
POWERMAX TFBG Series Biomass Gasification Power Generation System Flow Chart(TFBG-Twin-Fire Fixed Bed Gasifer)
- 1. Skip Charger
- 2. Biomass Gasifier
- 3. Dry Ash Discharger
- 4. Cyclone Dust Collector
- 5. Hot Air Heat Exchanger
- 6. Air Cooler
- 7. Gas Cooler
- 8. ESP
- 9. Gas Cooler
- 10. Gas Dryer
- 11. Buffer Tank
- 12. Gas Flare
- 13. Gas Generator Sets
- 14. Blower
- 15. Gas Compressor
Technical Specification of TFBG series Biomass Gasification Power Generation System
Model | 50TFBG | 100TFBG | 200TFBG | 300TFBG | 400TFBG | 500TFBG | 600TFBG | 800TFBG | 1000TFBG | 1200TFBG | 1500TFBG | 2000TFBG |
Rated Power(kw) | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Rated Frequency | 50 /60 HZ | |||||||||||
Rated Voltage(V) | 220 / 400 / 440 / 6300 / 6600 / 11000 /13800 | |||||||||||
Model of Gasifier | TFBG50 | TFBG100 | TFBG200 | TFBG300 | TFBG400 | TFBG500 | TFBG600 | TFBG800 | TFBG1000 | TFBG1200 | TFBG1500 | TFBG2000 |
Gasifier Type | Twin-Fire Fixed Bed Gasifier | |||||||||||
Biomass Moisture Requirement | ≤20~35%(wet basis) | |||||||||||
Biomass Size Requirment | Diameter 20mm-80mm;Length 10-80mm; | |||||||||||
Biomass Consumption(Kg/hr) | 50-100 | 100-200 | 200-400 | 300-600 | 400-800 | 500-1000 | 600-1200 | 800-1600 | 1000-2000 | 1200-2400 | 1500-3000 | 2000-4000 |
Gas Production(Nm3/h) | 125-150 | 250-300 | 500-600 | 750-900 | 1000-1200 | 1250-1500 | 1500-1800 | 2000-2400 | 2500-3000 | 3000-3600 | 3750-4500 | 5000-6000 |
Ash Discharge Type | Wet Ash Type/ Dry Ash Type | |||||||||||
Type of Gas Purification | Dry Type Gas Purification System | |||||||||||
Heat Value of Gas | ≥1200Kcal/Nm3 | |||||||||||
Gas Composition | CO-15~20%, CO2-8~12%, CH4-upto 3% H2-15~20% N2-45~50% | |||||||||||
Model of Gensent | 50GFLS | 100GFLS | 100GFLS | 300GFLS | 400GFLS | 500GFLS | 300GFLS | 400GFLS | 1000GFLS | 400GFLS | 500GFLS | 1000GFLS |
Qty of Genset | 1 | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 | 3 | 3 | 2 |
- 1.Elevator
- 2.Gasifier
- 3.Cyclone
- 4.Air Cooler
- 5.Indirect Cooler
- 6.ESP
- 7.Isolation Seal
- 8.Booster Fan
- 9.Indirect Cooler
- 10.Water Drop Catcher
- 11.Water Bleeding
- 12.Gas Flare
- 13.Buffer Tank
- 14.Gas Generator Set
- 15.Air Blower
- 16.Cooling Tower
- 17.Water Pump
- 18.Cooling Water Pooling
- 19.Condensate Water Pool
- 20.Tar Tank
- 21.Hot Air Heat Exchanger
Feedback form contact with us